In order to achieve 3D volume imaging, you need to use a confocal microscope, a light sheet microscope, or a single/multiphoton microscope. Refractive index mismatch is the main problem encountered when imaging cleared tissues. Visikol® HISTO™ cleared specimens have a refractive index of 1.51 or 1.53 (Visikol HISTO-1 or Visikol HISTO-2), very equivalent to glass.

Kwik Sil Epoxy Putty

How to get started

Description: Made with the highest-quality epoxy resins to adhere to steel, glass, masonry and most plastics. Kwik-Sil is a translucent, medium-viscosity silicone adhesive, developed for chronic peripheral nerve studies such as anterograde tracing with fl uorescent indicators or electrode recording. Good adhesion and mechanical properties (tear strength and elongation) allow days of.

There are several major considerations to keep in mind when imaging your tissues in 3D to ensure that you achieve the best results while spending the least amount of time optimizing your protocol.

Sil
  1. Minimize the volume of tissue that you need to image: 1 mm tissues can be imaged with any 3D microscope with any objective and thus greatly reduces not only imaging complexities but also tissue processing time if conducting immunolabeling. You can always reconstruct several 1 mm sections back together later.
  2. Minimize the amount of data you collect: while it might sound great to image a whole mouse brain with 40X magnification, is this amount of data actually required for your research question. Try acquiring as little data as possible from your tissue by using regions of interest, large Z-step sizes or lower magnification objectives.
  3. Understand the limitations of your microscope system: many objectives will be limited in their imaging depth by their working distance which is the maximum distance you can image with a specific objective. Low expression of fluorophores can also lead to shallow imaging depths due to rapid fluorophore quenching or simply not getting enough signal back to your detector.

Confocal microscopy

Confocal microscopy is an excellent tool for imaging thicker tissue specimens due to the nature of how a confocal microscope works. A confocal microscope uses a confocal lens setup in order to eliminate out-of-focus light from getting to the detector, resulting in “optical sections” that can be assembled digitally into volume images. There are many types of confocal microscope systems, both upright and inverted, with a variety of lasers, detectors, and objectives that may require specific considerations before imaging cleared tissues.

The most important consideration to make prior to imaging cleared tissue specimens is about the microscope objective available on the confocal instrument. The two most important aspects to consider about the microscope objective are 1) whether the objective is an air, water, glycerol, or oil objective; and 2) the working distance and numerical aperture of the objective lens.

Light sheet microscopy

First, you should reach out to your imaging core manager and find out what type of light sheet microscope you have access to and what type of objectives it uses. Many light sheet microscopes such as the ZEISS Z.1 and the OpenSPIM will have water immersion objectives that are matched to a refractive index of 1.33. These objectives have two disadvantages for imaging tissues that have been cleared with Visikol HISTO-2: 1) The mismatch in refractive index between the objective and Visikol HISTO-2 (1.53) will limit imaging depth to approx. 3 mm due to spherical aberrations and overall sample thickness to 6 mm if you image from both sides, 2) The sample will need to be mounted in a cuvette that is placed within the imaging chamber.

The reason that the sample will need to be mounted in a separate cuvette is that the imaging chamber cannot be filled with Visikol HISTO-2 when using water immersion objectives as it is possible that the objective can be damaged by Visikol HISTO-2. Information on the preparation of samples cleared with solvent based techniques (Visikol HISTO-2, BABB, 3/i/uDISCO) for light sheet microscopy with water immersion objectives can be found here for the ZEISS Z.1. However, if you have a solvent compatible light sheet imaging system like the LaVision BioTec Ultramicroscope then you can image directly in Visikol HISTO-2. The LaVision BioTec Ultramicroscope has been designed to work with almost every clearing solution (1.33 to 1.56) and will not get damaged by solvents.

Imaging with air objectives

Important: If you image your samples with an air objective, the maximum depth obtainable is approximately 500-1,000 microns deep caused to attenuation of the signal due to refractive index mismatch. To image thicker specimens / whole organs, you must utilize glycerol immersion objectives (e.g. glycerol immersion lens, CLARITY optimized objective, see table below for specific objectives), a multi-immersion objective with a refractive index adjusting collar, or utilize a light sheet microscope (discussed below).

Kwik-sil Epoxy

While air objectives are not ideal for visualizing whole organs, excellent results can and have been obtained for tissues up to 1-2 mm thick. This is accomplished by visualizing tissues 500-1000 µm thick and then flipping the tissue over, and repeating. One can compensate somewhat for attenuation of signal by adjusting the gain setting as the scan proceeds through the cleared tissue. There may be some spherical aberration as depth approaches the maximum, and this may result in “smearing” across the z-axis (this can easily be seen in xz or yz projections of image stacks in ImageJ by going to command Image>Stacks>Orthogonal Views).

Most air objectives have a working distance of several millimeters, and so the only limit to imaging is related to the attenuation of signal from aberration. A numerical aperture (NA) of less than 0.3 is not appropriate for volume imaging, as the depth of field at 500 nm wavelength light is >40 microns, which is insufficient z-resolution for volume imaging, since adjacent optical sections will bleed through to the focal plane with such a wide depth of field.

Mounting specimens for imaging with an air objective

Epoxy

There are several options for how to mount cleared samples with an air objective which essentially involve enclosing the specimen in a chamber filled with Visikol HISTO-2:

  1. 3D print a chamber to enclose your sample
    • Our starter kit includes a chamber that you can use for 3D imaging.
    • You can also make your own, provided you have a 3D printer, as most universities now do, this is one of the easiest and least expensive methods to create an imaging chamber. If you do not have access to a 3D printer, there are many online services, such as 3DHubs, where you can upload a file and they will send your 3D-printed part to you. However, Visikol HISTO-2 will degrade PLA/ABS and we suggest using a resin-based 3D printer like the Formlabs Form2.
    • You can seal your chamber with LOCTITE® FUN-TAK®, or alternatively, Kwik-sil epoxy, a non-permanent adhesive.
  2. Use ClearWells™: silicon isolating chambers to create a well on a glass slide
    • Using stack-able silicon chambers cut into circular wells is the simplest way to construct an imaging chamber

Imaging with immersion objectives

Due to aberrations caused by refractive index mismatch between air and glass presenting absolute limits on resolution, immersion objectives were developed to reduce scattering and noise caused from refractive aberrations. Immersion objectives are well-suited to deep tissue imaging due to the resultant reduction of refractive index mismatch between sample and objective, as the lens is immersed directly in the medium, eliminating mismatch between the liquid medium and air typically encountered for air lenses.

Kwik sil epoxy putty

Oil immersion lenses work very well with Visikol HISTO cleared specimens, however the working distance on oil immersion lenses is typically 250 microns or less, which presents a 500 micron limit on the thickness of tissue to image.

Since some objectives may be corroded or damaged from immersion in Visikol HISTO-2, you should utilize the double chambered cuvette that comes in our Starter Kit. The cuvette allows the sample to be mounted in Visikol HISTO-2, and the immersion objective to be immersed in an alternate medium (water or glycerol).

Water immersion lenses allow for 2-3 mm depth of imaging, however some refractive index mismatch will still occur, since water has a refractive index (1.33) significantly different than Visikol HISTO-2 (1.53).

Kwik Sil Epoxy Resin

Sil

A further improvement in imaging depth can be obtained by using glycerol immersion objectives. Some refractive mismatch will still occur, however substantially less aberration will result due to the closer match in refractive index between glycerol (1.47) and Visikol HISTO-2 (1.53). Double chambered cuvettes should be used.

For optimum results when imaging very thick tissues (> 1 mm) or whole organs, one should use multi-immersion objectives containing a correction collar. However, a correction collar isn’t required for immersion objectives as long as proper optical design has been done to allow imaging over a range of RI. These objectives (shown in the table above) offer the deepest tissue imaging, allowing for imaging of complete, intact organ systems. The only limitation to depth with these objectives is the effective working distance, since a sample approximately twice the thickness of the working distance length can be imaged.

Model (Manufacturer)Working DistanceNumerical AperatureRefractive Index Range
Leica - 25X FLUOTAR6 mm1.01.45
Zeiss - 20X LSFM Clearing5.61.01.45
Olympus - 10X UIS2-XLPN10XSVMP8 mm0.61.33-1.52
Olympus - 25X UIS2-XLSPLN25XGMP8 mm1.01.41-1.52
ASI - Immersion Objectivefor Cleared Tissues12 mm0.37-0.431.33-1.56

Mounting specimens

For mounting specimens for imaging, we suggest using ClearWells. The sample is placed in the well, covered with Visikol HISTO-2 and then a cover slip is placed on top of the slide.

Skip to end of metadataGo to start of metadata

Model labels: DetChannelAssby:1, DetChannelAssby:2

The goal is to couple the lens onto the PMT face with oil
Seal around the edge of the window that is on top of the PMT photocathode, so that oil can not leak into the body of the PMT, with 5 min epoxy. Be careful not to soil the plate above the photocathode.
Place condensor lens on oil–touch to oil on one side first so as not to trap large bubble underneath. Make sure there are no bubbles and carefully remove overflow oil from the housing.
Place a thin ring of Kwik-Sil (WPI) on the PMT housing around the lens
Add PMTMountPlate before Kwik-Sil sets, such that sealant squishes between the lens and PMTMountPlate. Hold lens down so that it does not move up while mount plate is being pushed down. Attach PMTMountPlate to PMT with two M3 screws.

Kwik Sil Epoxy Adhesive

Allow ~30 minutes at least for Kwik-Sil to set (oil mixing with Kwik-Sil will interfere with the setting process).
Hold PMT in vise with window side down for several minutes to check if there is oil leakage. Blow gently around seal with canned air to see if there is movement of liquids/uncured Kwik-Sil.
If there is leakage, seal further between the condenser lens and PMTMountPlate using epoxy, or other sealant. It is OK if the sealant touches the face of the condenser lens a couple mm above where this lens meets the edge of the PMT mount plate.
Hold PMT at angle it will be used in microscope (depending on red or green channel) overnight, and check again that oil coverage between the condenser lens and PMT window is intact. There should be no obvious bubbles or inhomogeneities when looking at the photocathode through the condenser lens.

UV cement method

Note: applying UV light to cure UV cement will not harm the PMT photocathode. There have been problems when using UV cement with thick layers of cement (few hundred micron), resulting in permanent bubbles present between the lens and PMT, but the strategy below should not have such problems. It is currently untested, however.

Kwik-sil Epoxy Vwr

A relatively foolproof way to do the PMT condenser lens bonding with UV cement would be to fill the gap between the condenser lens (flat, optical surface) and the PMT window with another piece of glass (index of refraction ~1.5), and then only use thin UV cement layers, like when bonding a doublet lens, between all the glass pieces. Pieces of coverglass would work fine for this. It would just be necessary to find the right thickness of the gap-filling glass, such that there aren't any air gaps, and the condenser lens doesn't have to rise up much beyond its normal seating position (shoulder touching the PMT housing). Two to three #1.5 coverglass pieces ought to do it. After assembling everything dry to test the thickness and fit of the filler, the filler pieces could be cemented to the condenser lens first, and then whole assembly would be cemented to the PMT.